Liquid Tight Flexible Conduit Brief

Liquid-Tight Flexible Conduit Description

Metallic Vs Non Metallic Liquid Tight

Liquid Tight Flexible Nonmetallic Conduit Applications

Non Metallic Flexible Conduit

Flexible Metallic Conduit

GET Non Metallic Flexible Conduit OR Flexible Metallic Conduit PRODUCT



Liquid Tight Flexible Metal Conduit in external appearance resembles its close relative, liquid-tight flexible nonmetallic conduit. Both have smooth grey outer jackets that are liquid tight. Type Liquid Tight Flexible Nonmetallic Conduit has an internal steel shield, which makes it more powerful and much less at risk to kinking. Either of these raceways can be created in mild curves to change instructions and also to stay clear of challenges. Additionally, the versatility works for ending at motors where there is likely to be heavy vibration.

Liquid Tight Flexible Metal Conduit

Liquid Tight Flexible Metal Conduit

Use, installation, and construction specifications are found in NEC Short article 350, together with the critical Uses Permitted and also Uses Not Permitted. Liquid-tight flexible metal conduit is specified as a raceway of a round cross-section having an external liquid-tight, nonmetallic, sunlight-resistant jacket over an internal versatile metal sheath with linked combinings, connectors, and also installations for the installation of electric conductors.


Liquid-Tight Flexible Metal Conduit


Liquid-tight flexible metal conduit is allowed to be used in exposed or hidden locations where adaptability or protection from liquids, vapors or solids is required. It is permitted in specified unsafe (classified) places and also it may be used for direct interment where detailed and marked for the purpose.

Liquid-tight flexible metal conduit is not to be used where subject to physical damage.

There are some dimension limitations. Liquid-tight flexible metal conduit smaller sized than statistics designator 16 (trade dimension 1/2) is not to be utilized. However, an exemption permits metric designator 12 (trade size 3/8) for enclosing motor leads. The optimum dimension of Liquid-Tight Flexible Metal Conduit allowed is metric designator 103 (trade dimension 4).

The optimum number of bends is not to be a lot more that the equivalent of four quarter bends between pull factors. Subject to exemptions, liquid-tight adaptable steel conduit is to be safely secured in place within 12 in. of boxes, as well as protected at periods not over 4 1/2 ft.

If liquid-tight flexible metal conduit is used to minimize resonance to or supply flexibility for relocating tools, an equipment-grounding conductor must be provided. Or else, the internal metal sheath will certainly be adequate.

Liquid Tight Flexible Metal Conduit is a long lasting alternative wiring approach. Where suitable, it contributes to an attractive appearance in commercial and also commercial job and also operates well in domestic settings for powering water pumps and also fixed devices where there is ambient wetness in addition to resonance.


Flexible Metal Conduit Products

Non-metallic conduit

Non-metallic conduit is a versatile product that has a variety of applications for indoor and outdoor locations. Non-metallic conduit is used in fixture whips, data centers, electric signs and outdoor lighting, HVAC, pool and spas and locations with exposure to sunlight and weather conditions and more. Our non-metallic conduit has a rigid PVC core for strength and is rated for concrete embedment. Our non-metallic conduit Type LFNC-B is available in long length reels in sizes 1/2” to 1”.  Non-metallic conduit is used with non-metallic liquidtight connectors

Material:PA

Temperature Range : -18℃~+105℃

IP Rating : 

IP 66 (Fit with connector series: FN01, FN02, FN03 and FN04)

IP 68 (Fit with connector series: FN50 & FN53)

Jacket Color : Black (Standard), other colors are available by consult.

Flexibility : High

Fire Retardant : V0

UV Resistance : Yes

RoHS Compliance : Yes

Certificate : CE, cURus

20170113025315447.jpg


metallic liquid tight conduit    

Applicable for the protection of circuit with 600 volts or lower in locations where UL certificate is required, including commercial buildings, industrial/power plant, shipyards, marine or boat, computer rooms and etc.

Material:Galvanized Steel + PVC Jacket

Temperature Range: 

-20℃~+105℃ Dry, 60℃ Wet, 70℃ Oil

-20℃~+80℃ Dry, 60℃ Wet, 70℃ Oil

-20℃~+60℃ Dry, 60℃ Wet, 60℃ Oil


IP Rating:IP 40 (Fit with connector series: S52), IP 66 (Fit with connector series: S50, S51 & S53), Jacket Color: Grey (Standard), other colors are available by consult.

Flexibility: Medium

Fire Retardant: Self-extinguishing

UV Resistance: Yes

RoHS Compliance: Yes


If need contact us!